The Aprilaire 800 Steam Humidifier Manual provides essential guidance for installing‚ operating‚ and maintaining your steam humidifier․ It covers key components‚ safety precautions‚ and troubleshooting tips to ensure optimal performance and longevity of the unit․
Key Components of the Aprilaire 800 Steam Humidifier
The Aprilaire 800 Steam Humidifier features key components like electrodes‚ a canister‚ fill valve‚ overflow reservoir‚ and an optional fan pack for efficient steam distribution and operation․
Electrodes and Steam Generation
The Aprilaire 800 Steam Humidifier uses electrodes submerged in water within a canister to generate steam․ When energized‚ current flows between the electrodes‚ causing the water to boil and produce steam․ This system operates effectively with water conductivity between 100 and 1‚250 uS/cm‚ suitable for both hard and softened water․ The electrodes are a critical component‚ ensuring efficient steam production for humidity control in residential spaces․
Canister and Water Supply System
The Aprilaire 800 Steam Humidifier features a canister that holds water‚ which is introduced through a fill valve into a fill cup․ This fill cup doubles as an overflow reservoir‚ ensuring proper water levels․ The system is designed to work with both hard and softened water‚ providing reliable steam generation․ Regular maintenance of the canister and water supply system is crucial to prevent mineral buildup and ensure optimal performance․
Fill Valve and Overflow Reservoir
The fill valve automatically regulates water flow into the canister‚ ensuring the correct water level․ The overflow reservoir prevents excessive water accumulation‚ safeguarding against leaks and overflows․ Proper function of these components is vital for efficient steam generation and system longevity․ Regular inspection and maintenance are recommended to ensure optimal performance and prevent potential issues․
Installation Requirements and Recommendations
The Aprilaire 800 should be installed in a well-ventilated area‚ away from direct sunlight and heat sources․ Ensure a stable water supply‚ proper drainage‚ and correct electrical connections for optimal performance․
Mounting the Humidifier
The Aprilaire 800 must be mounted securely on a wall or floor‚ ensuring it is level and stable․ Use the provided mounting hardware to attach the unit firmly․ The humidifier should be installed in a location that allows easy access for maintenance and ensures proper water drainage․ Follow the manual’s guidelines for minimum clearances to avoid obstructions and ensure safe operation․
Connecting Water Supply and Drain
Connect the water supply line to the fill valve‚ ensuring it is securely attached to prevent leaks․ Install a drain hose from the overflow reservoir to a suitable drain location․ Verify that the water supply pressure does not exceed 120 psi to avoid overflow issues․ Properly align and secure all connections to ensure reliable operation and prevent water damage․
Installing the Optional Fan Pack
Mount the Aprilaire Model 850 Fan Pack near the humidifier‚ ensuring proper alignment․ Connect the steam outlet to the fan pack’s inlet and secure all duct connections․ Follow manual instructions for wiring the fan pack to the humidifier and HVAC system․ Ensure the fan pack is level and properly vented to maximize steam distribution efficiency and system performance․
Operating Principles of the Aprilaire 800
The Aprilaire 800 generates steam by energizing electrodes in a water-filled canister‚ creating humidity distributed through the HVAC system or optional fan pack․
How Steam is Generated
The Aprilaire 800 generates steam by energizing two electrodes submerged in a water-filled canister․ When the humidistat detects low humidity‚ the fill valve refills the canister․ The electrodes then heat the water to boiling‚ producing steam․ The canister’s overflow reservoir ensures proper water levels․ This system operates efficiently with water conductivity between 100 and 1‚250 μS/cm‚ suitable for both hard and softened water conditions․
Role of the Humidistat in Operation
The humidistat plays a crucial role in regulating the Aprilaire 800 Steam Humidifier by monitoring indoor humidity levels․ When the desired humidity setpoint is reached‚ it deactivates the humidifier․ If humidity drops below the setpoint‚ the humidistat signals the unit to generate steam‚ ensuring consistent humidity levels․ This automatic control prevents over-humidification and maintains optimal indoor comfort efficiently․
Steam Distribution Through HVAC System
The Aprilaire 800 distributes steam through the HVAC system using a dispersion tube installed in the ductwork․ This ensures even humidity distribution throughout the home․ The system can also operate with the optional Model 850 Fan Pack‚ allowing steam distribution without the HVAC running․ This setup provides consistent humidity levels and prevents over-humidification‚ ensuring a comfortable indoor environment year-round․
Maintenance and Care Instructions
Cleaning the Canister and Electrodes
Regularly clean the canister and electrodes to maintain efficiency and prevent mineral buildup․ Drain and rinse the canister‚ and soak it in a vinegar solution to remove scale deposits․ Gently scrub electrodes with a soft brush to ensure proper steam generation․ Avoid using abrasive materials that could damage the components․ Cleaning ensures optimal performance and prevents corrosion‚ which can lead to reduced humidity output or system damage over time․
Replacing Parts and Filters
Replace the canister and electrodes every 1-3 years or as needed to maintain efficiency․ Check and replace the water filter annually to ensure clean water supply․ Always turn off power before servicing․ Dispose of old parts responsibly․ Use genuine Aprilaire replacement parts for optimal performance․ Refer to the manual for detailed replacement procedures and guidelines to ensure proper installation and functionality of the humidifier․
Winterizing the Humidifier
Drain the water from the canister and supply line to prevent freezing․ Disconnect the water supply line and drain thoroughly․ Clean the canister and electrodes to remove mineral buildup․ Ensure all components are dry to avoid damage during colder months․ Follow the manual’s winterization steps to maintain the humidifier’s efficiency and longevity when not in use during the winter season․
Troubleshooting Common Issues
Identify common issues like humidifier malfunction‚ low steam output‚ or water leaks․ Check power supply‚ water flow‚ and drain lines for blockages or damage․ Consult the manual for solutions or contact Aprilaire support if problems persist․
Humidifier Not Turning On
If the Aprilaire 800 fails to turn on‚ first check the power supply and ensure it’s properly plugged in․ Verify that the circuit breaker or fuse hasn’t tripped․ Inspect the humidistat settings to ensure it’s activated and set correctly․ Also‚ check for any blockages in the water supply line or drainage system․ Consult the manual for detailed diagnostic steps or contact Aprilaire support for assistance․
Low Steam Output or No Steam
If the Aprilaire 800 produces low steam or no steam‚ check the water supply pressure and ensure it’s within the recommended range (100-1‚250 µS/cm)․ Inspect the electrodes for mineral buildup and clean them if necessary․ Verify the fill valve operation and ensure the overflow reservoir isn’t clogged․ Also‚ check for blockages in the steam hose or dispersion tube․ Refer to the manual for detailed troubleshooting steps to restore proper steam generation․
Water Leaks or Overflow
Water leaks or overflow in the Aprilaire 800 may result from excessive supply pressure or a malfunctioning fill valve․ Ensure the water pressure does not exceed 120 psi․ Check for blockages in the overflow reservoir and clean the fill cup regularly․ Inspect the canister and connections for any cracks or loose fittings․ Addressing these issues promptly prevents water damage and maintains efficient humidifier operation․
Safety Precautions and Warnings
Always handle the Aprilaire 800 with care‚ as it involves extremely hot surfaces and steam that can cause severe burns․ Avoid touching the canister‚ steam dispersion tube‚ or discharged water․ Ensure proper installation and maintenance to prevent accidents and maintain safe operation․
General Safety Guidelines
Always follow the Aprilaire 800 manual’s safety guidelines to avoid accidents․ Keep children away from hot surfaces and steam․ Ensure proper installation and maintenance to prevent hazards․ Use only approved components and adhere to voltage requirements․ Regularly inspect for leaks or damage․ Never modify the unit or bypass safety features․ Proper drainage is essential to avoid water damage․ Refer to the manual for detailed safety precautions and warnings․
Handling Hot Surfaces and Steam
The Aprilaire 800 Steam Humidifier operates with extremely hot surfaces‚ including the canister‚ steam pipes‚ and dispersion tube‚ which can reach up to 212°F․ Avoid direct contact with these components to prevent burns․ Steam discharged from the system may not be visible but can still cause injury․ Always handle the unit with caution‚ and ensure the area around it is clear of flammable materials․ Never touch hot surfaces without proper protection․
Electrical Safety Considerations
Ensure the Aprilaire 800 Steam Humidifier is installed by a licensed electrician‚ adhering to local codes and manufacturer guidelines․ Use a dedicated 120V circuit with a 20A GFCI breaker to avoid power issues․ Keep electrical components dry and avoid modifying the unit’s wiring․ Disconnect power before maintenance to prevent shocks․ Always follow the manual’s wiring diagram and safety protocols for safe operation and to minimize electrical hazards․
Warranty and Support Information
The Aprilaire 800 Steam Humidifier is backed by a comprehensive manufacturer warranty․ For support‚ contact Aprilaire Tech Support or visit their official website for online resources and manuals․
Manufacturer Warranty Details
Aprilaire offers a comprehensive warranty for the Model 800 Steam Humidifier‚ covering parts and labor for a specified period․ The warranty ensures protection against defects in materials and workmanship․ Proper installation and maintenance are required to uphold warranty validity․ For detailed terms and conditions‚ refer to the official Aprilaire website or the provided manual․ Contact Aprilaire support for any warranty-related inquiries or claims․
Contacting Aprilaire Tech Support
For assistance with the Aprilaire 800 Steam Humidifier‚ contact Aprilaire Tech Support toll-free at 1-800-334-6011․ Representatives are available to address technical questions‚ troubleshooting‚ and warranty inquiries․ Additionally‚ visit the official Aprilaire website for online support resources‚ including FAQs‚ manuals‚ and contact forms․ Ensure to have your model number and serial number ready for efficient service․
Online Resources and Manuals
Access the Aprilaire 800 Steam Humidifier manual and additional resources on the official Aprilaire website․ Download PDF manuals‚ installation guides‚ and troubleshooting tips․ Visit Aprilaire․com for comprehensive support‚ including FAQs and product specifications․ These resources ensure proper installation‚ maintenance‚ and operation of your humidifier‚ maximizing its performance and longevity․
By following the Aprilaire 800 Steam Humidifier Manual‚ you ensure optimal performance‚ safety‚ and longevity of your unit․ Proper installation‚ maintenance‚ and operation will enhance indoor air quality and comfort․ Regularly review the manual for troubleshooting and maintenance tips to keep your humidifier functioning efficiently․ For additional support‚ refer to online resources and manufacturer guidelines to maximize the benefits of your Aprilaire 800 Steam Humidifier․